top of page
Black on transparent.png
Master Card Logo
VISA logo
Paypal.png
Apple Pay.png
G Pay.png
Accuenergy - AcuCT-H040 Hinged CT 5–60A : 333mV (Window 10.2mm)

Description:

The Accuenergy AcuCT Hinged Series is a family of high-accuracy, ultra-compact hinged split-core current transformers with a safe 333mV output, designed for monitoring branch circuits in crowded electrical panels. The installer-friendly hinged design snaps around the conductor for rapid installation. Four round window sizes cover 1A to 600A: AcuCT-H040 (10.2mm), AcuCT-H063 (16mm), AcuCT-H100 (25.4mm) and AcuCT-H138 (35mm). Accuracy is 0.5% class, with the H100 and H138 compliant with IEC 61869-2 Class 0.5. All models ship with 2.5m (8ft) leads, operate from -25°C to 70°C and are UL Recognised, CE and RoHS.

 

Key Features:

  • Hinged split-core design for quick installation in crowded panels

  • Ultra-compact form factor ideal for branch-circuit monitoring

  • Safe, low-voltage 333mV output

  • Accuracy class 0.5% (AcuCT-H040 1A and 5A ratings: 1%); AcuCT-H100 and -H138 compliant with IEC 61869-2 Class 0.5

  • Rated currents from 1A to 600A across four window sizes (10.2mm to 35mm)

  • Rated voltage 600VAC; withstand voltage 3.0kV / 1mA / 1 min

  • Wide operating temperature -25°C to 70°C

  • 2.5m (8ft) 22AWG twisted-pair lead wires

  • Black nylon UL 94V-0 housing

  • Certifications: CE, RoHS, cURus (E359521); IEC 61869-2 (H100, H138)

 

Technical Specifications:

  • Model: AcuCT-H040 – hinged current transformer, 333mV output, window 10.2mm, rated primary current 5–60A. Ultra-compact hinged design for branch circuits.

  • Output: 333mV

  • Accuracy: 0.5% class (H040 1A/5A ratings 1%); IEC 61869-2 Class 0.5 on AcuCT-H100 and AcuCT-H138

  • Current range: 10% - 120% of rated (H040, H063); 5% - 120% of rated (H100, H138)

  • Rated primary currents: AcuCT-H040 1/5/10/15/20/30/40/50/60A; AcuCT-H063 5/30/50/75/100/150A; AcuCT-H100 10/20/30/50/60/100/120/150/200/250A; AcuCT-H138 200/250/300/400/500/600A

  • Window sizes: AcuCT-H040 10.2mm (0.40in); AcuCT-H063 16.0mm (0.63in); AcuCT-H100 25.4mm (1.00in); AcuCT-H138 35.0mm (1.38in)

  • Dimensions (W x H x D): H040 29.4 x 26.4 x 41.7mm; H063 36.0 x 30.5 x 53.0mm; H100 50.8 x 38.6 x 70.1mm; H138 65.0 x 40.0 x 83.0mm

  • Frequency: 50Hz - 1kHz (50 - 400Hz as stated in datasheet)

  • Rated voltage: 600VAC

  • Withstand voltage: 3.0kV / 1mA / 1 min

  • Lead wires: 2.5m (8ft) twisted pair, 22AWG; white = positive, black = negative

  • Operating temperature: -25°C to 70°C (-13°F to 158°F)

  • Operating humidity: 0 to 95% RH non-condensing

 

Ordering Options (Rated Primary Current):

  • AcuCT-H040-5:333 – 5A : 333mV

  • AcuCT-H040-20:333 – 20A : 333mV

  • AcuCT-H040-30:333 – 30A : 333mV

  • AcuCT-H040-40:333 – 40A : 333mV

  • AcuCT-H040-50:333 – 50A : 333mV

  • AcuCT-H040-60:333 – 60A : 333mV

 

Lead Time:

1 - 3 Days.

Accuenergy - AcuCT-H040 Hinged CT 5–60A : 333mV (Window 10.2mm)

396,00 ZARPreço
Quantidade
bottom of page