Description:
The Acuvim L is a cost-effective multifunction power and energy meter for panel and device monitoring in commercial and industrial installations. It provides revenue-grade accuracy (Acuvim EL: IEC 62053-22 Class 0.2s / ANSI C12.20 Class 0.2; Acuvim CL: Class 0.5s / Class 0.5), four-quadrant metering, harmonics, alarms, Time-of-Use and 8 MB of onboard logging. An RS485 port with Modbus-RTU and BACnet MS/TP is standard, and the same AXM I/O and communication modules used by the Acuvim II add Ethernet, Wi-Fi, fibre and protocols such as Modbus-TCP, BACnet-IP, IEC 61850, PROFINET and MQTT.
Key Features:
Acuvim EL: ANSI C12.20 Class 0.2 and IEC 62053-22 Class 0.2s; Acuvim CL: ANSI C12.20 Class 0.5 and IEC 62053-22 Class 0.5s
Voltage and current inputs 0.1% of reading accuracy; 512 samples/cycle; 45-65 Hz auto-adaptive frequency
Individual harmonics 2nd to 63rd (EL) or 2nd to 31st (CL), THD, K-factor, crest factor, THFF
4th CT input for neutral current; four-quadrant power and energy; demand for current, power and reactive power
Up to 16 alarm limits (over/under) selectable from 80 parameters
Time-of-Use with up to four tariffs (sharp, peak, valley, normal)
8 MB onboard memory, three assignable historical logs and real-time clock; expandable to 8 GB logging with AXM-WEB2
Standard RS485 port with Modbus-RTU and BACnet MS/TP, 2400-115200 bps; 1 s LCD refresh, 100 ms Modbus data update
Optional AXM-WEB2, AXM-WEB2-D, AXM-WEB2-FOLC, AXM-NET2 and AXM-RS485 communication modules (Modbus-TCP, BACnet-IP, IEC 61850 2nd Ed., DNP3, SNMP v3, PROFINET, MQTT, HTTP/HTTPS)
Up to 3 optional AXM-IO1/IO2/IO3 modules for digital inputs, relay/digital outputs and analog I/O
Technical Specifications:
Model: Acuvim CL-D – IEC 62053-22 Class 0.5S / ANSI C12.20 Class 0.5, harmonics to 31st, 96 x 96mm LCD panel mount
Voltage input: nominal 480 Vac L-N / 828 Vac L-L; 1500 Vac continuous withstand, 2500 Vac 1 min; 2 MOhm per phase; 10 Vac pickup; accuracy 0.1% of reading
Current input (5A option): 5 A or 1 A field selectable, 0-10 A / 0-2 A range, 5 mA / 1 mA pickup, burden 0.05 VA at 5 A
Current input (mV option): 333 mV or Rogowski coil field selectable, 0-400 mV range, 0.25 mV pickup
Frequency: 45-65 Hz
Accuracy: EL Class 0.2s (IEC 62053-22) / Class 0.2 (ANSI C12.20); CL Class 0.5s (IEC 62053-22) / Class 0.5 (ANSI C12.20)
Harmonics: EL 2nd-63rd, CL 2nd-31st, 0.1% resolution
Sampling: 512 samples/cycle; LCD refresh 1 s; Modbus data update 100 ms
Auxiliary power P1V4: 100-415 Vac 50/60 Hz or 100-300 Vdc; P2V4: 20-60 Vdc; burden 5 W; 3250 Vac 1 min withstand; Installation Cat III
Communication (standard): RS485 2-wire, Modbus-RTU and BACnet MS/TP, 2400-115200 bps
Communication (optional): AXM-WEB2 (dual Ethernet + Wi-Fi), AXM-WEB2-D (dual Ethernet), AXM-WEB2-FOLC (fibre LC + Ethernet + Wi-Fi), AXM-NET2 (single Ethernet Modbus-TCP), AXM-RS485
I/O modules (max 3): AXM-IO1 6 DI + 2 relay + 24 Vdc; AXM-IO2 4 DI + 2 DO + 2 AO; AXM-IO3 4 DI + 2 relay + 2 AI; DI 20-160 V ac/dc dry contact; relay 250 Vac / 30 Vdc, 5 A resistive; analog 0-5 V/1-5 V/0-20 mA/4-20 mA
Display: LCD on panel-mount D model; M model no display, optional REM-DS1V4 remote display via 6 ft 10-pin RJ50 cable
Ordering Options (Current Input & Auxiliary Supply):
Acuvim-CL-D-5A-P1V4 – 5A/1A CT input, 100-415VAC / 100-300VDC supply
Acuvim-CL-D-5A-P2V4 – 5A/1A CT input, 20-60VDC supply
Acuvim-CL-D-mV-P1V4 – 333mV / Rogowski input, 100-415VAC / 100-300VDC supply
Acuvim-CL-D-mV-P2V4 – 333mV / Rogowski input, 20-60VDC supply
Lead Time:
1 - 3 Days.
Online monitoring add-on: choose "Add 12 months online monitoring" to include a year of the UtilityPal App for this meter - automated readings, consumption and cost reporting, and your own online login. R1056 VAT included, the same as the UtilityPal App 12-months-prepaid rate.